Control and monitor commercial and residential gates with ControlByWeb devices - Connect the relays to a gate controller to remotely control the gate. Monitor the gate's status with digital inputs. You can schedule the gate to open during regular business hours.
You have full control over when the gate opens and you can receive text or email alerts if the gate is opened after-hours.Use a temperature sensor to control a relay, which in turn can control a heater. The X-410 can activate the heater to prevent motor freeze up and melt ice. Security Gate Control & MonitoringIn this example, the gate's motor controller is connected to one of the X-410's relays. A stand-alone keypad controller is connected to one of the X-410 inputs. When a correct code is entered into the keypad, the keypad outputs a signal to the X-410. The X-410 activates the gate's motor when signaled from the keypad or when an authorized user activates the gate through the X-410 using a web browser or CBW Mobile app.
The Linear Pro Access line of access controls are built to meet the wide range of system requirements while providing high. Door/Gate Access Controllers.
The X-410 also monitors whether the gate is open or closed by connecting a switch or sensor to another input on the X-410.Limit access during scheduled times.The X-410 can be easily programmed so that after 10PM, the gate cannot be opened from the outside of the facility; however, a loop detector connected to a digital input allows the gate to be automatically opened from the inside until 11PM. After 11PM, the relay is disabled and the gate remains closed unless opened by an authorized user. If the gate is opened after-hours, it sends an email/text alert to key personnel.Monitor Motor TemperatureIn our example, the X-410 has a temperature sensor to monitor the motor temperature. A heater is wired to the X-410 so when the temperature gets too low, the X-410 can turn on the heater to prevent the motor from freezing.No Cloud Services or Monthly FeesThe X-410 is a stand-alone, independent device. There are no monthly fees, and no software to install. Xytronix Research & Design Inc. (ControlByWeb.com), strives to provide the utmost in quality products and customer satisfaction.
Our return policy is stated below:. Products may be returned within 30 days of purchase date for a full refund of the purchase price (excluding shipping). Items returned within that time frame may be opened, but must be in good, resellable condition and include all components (connectors, cables, etc.) that were shipped with the product(s). Note that orders over $1,000 that were purchased using a credit card will be subject to a 5% restocking fee. Unopened products that are returned more than 30 days but less than 90 days from date of purchase may be returned for a refund of the purchase price minus a 20% restocking fee. Custom products, special orders, large orders (orders greater than 40 pc), and items that are beyond 90 days from the purchase date may not be returned for a refund.Note: All of our products are fully supported and come with a 5-year warranty. See for more detail.To obtain a refund for a purchase, contact our to obtain an RMA before shipping.Xytronix Research & Design, Inc.1681 West 2960 SouthNibley, Utah 84321USA.
IP Doorphone & Intercom with Secure Door / Gate Control Relay - Easy Retrofit Solution for Analog SystemsThe 8028 doorphone is an outdoor rated SIP compliant intercom, designed to complement premise security and improve efficiency for greeting visitors and guests at a door or gate in business or residential applications. Any telephone or device in the UC environment can communicate with the 8028, with entry activated by a simple telephone keypress.VIDEO:The 8028 SIP Doorphone eliminates the need for an ATA or FXS port.
The intercom is full duplex capable, featuring an echo canceller for superior voice quality.This intercom is ideally suited for applications involving the upgrade/retrofit of an existing analog intercom to IP where twisted pair is only available. Installation is simple by wiring the 8028 door station intercom at an entrance or gate to a controller located inside the premise. The separate controller ensures that both the network connection and door opening control relay of the 8028 cannot be tampered with from the public-facing intercom. All door strikes and access control systems that provide a contact closure are compatible with the 8028.The 8028 door control relay can connect to any type of door release, gate activation system or access control panel.
The intercom includes a 24V 0.3 A power source for low power 24V DC door strikes (customer provided). Additionally, there are low current programmable inputs and outputs at both control unit and intercom station for door sensing, door unlock switch, door unlock override, auxiliary call buttons, or telephone status such as ringing or in-use.The 8028 kit includes the following: Door Station with a stainless steel face plate (brass is also available for purchase as a separate item), Controller with power supply, and a bezel for surface mounting. Please note that the Door Station can flush mount into a standard dual gang box. Mounting gaskets are included in the kit for installing the intercom in any outdoor environment.How it Works.
Visitors press the backlit call button on the 8028 door station intercom to initiate pre-configured calling to one or more telephones (e.g. Hunt group). Answering the intercom call enables two-way communication with the visitor. Accepts a call when calling the doorphone directly. Pressing a pre-configured door open code (e.g. Digit 6) from the telephone or device (e.g.